Product Details:
Place of Origin: China
Brand Name: Pengyus
Certification: ISO
Model Number: CX-7448
Usage: Home, Office, Industry, Hotel
Display: LCD
Defend zones: 365*310*85mm
Input voltage: AC18V 50W
Port: shenzhen
Payment & Shipping Terms:
Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: According to customer’s requirment
Delivery Time: 7-15days
Payment Terms: L/C,T/T,Paypal
Contact Now
Detailed Product Description
High Light:

wired alarm systems

,

security alarm systems

Wired alarm system>BUS system Intelligent Wired Alarm System  CX-7448

Model:CX-7448

BUS system Intelligent Wired Alarm System CX-7448>Brief Description

1.200 groups user password.
2. LCD display
3.Support two-way communication
4.support GSM, network alarm

BUS system Intelligent Wired Alarm System CX-7448>Features

New Function

* Dual Serial Ports, access to wired and wireless keyboard.
* Support two-way communication, enable work with 8 dual-way wried keypad, 8 dual-way wireless keypad, 8 dual-way remote.
* support GSM and TCP/IP protocol, network alarm settings.
* dopt bran new 16 bit MCU.

Basic Function

* LCD display, convenient and flexible man and machine operation interface
* 8 zones which can be expanded to 240 zones, total 248 zones.
* The length of bus up to 2.0km (dia.1.5mm).
* Support 15 keypads, all the zones could be distributed to 8partitions which can be armed/ disarmed independently.
* 200 groups user password, 30 programmable zones.
* Many kinds of multiple zones expansion module:  8 zones expansion module CX-7408; single zone expansion moduleCX-7401; dual zone expansion module CX-7402; 6 zones expansion module CX-; and detector with address code.
* Auxiliary output bus interface supports CX-7412, CX-32B relay output module and another accessory.
* Connected with computer through CX-7412, or connected withLAN through interface.
* Connected with CMS through PSTN, support 4+2, CONTACT ID.
* Programming through keypad or remote programming.
* Support wireless expansion function: 2 wireless receiver, 112 wireless detectors or buttons, 5 wireless keypads.

BUS system Intelligent Wired Alarm System CX-7448>Parameter:

Product Model CX-7664
Communication method PSTN
Max output power consumption 12VDC;500mA
Suitable temperature -10°C~55°C
Response time 200~800ms
Humidity <90%
Zone 16 wired and 16 wireless
Power supply 220VAC±10%;50Hz
Wireless receiving 315M (433 is optional) enrolling code
Communication protocol Contact ID(ADEMCO)
Programming method through telephone, wireless keypad, remote
Programmable receiving telephone 6 groups of telephone numbers
Arming/disarming through remote controller, wireless keypad, phone,  
Standby power 12VDC;1.3Ah
Message recording 20s
Inquiry memory 1 start time, 2 time for arming/disarming, 4 alarm information
Alarm output NC/NO, 1A 12VAC/24VDC

BUS system Intelligent Wired Alarm System CX-7448>accessory:

*Working independently, or connected with CX-7448 BUS
*6 alarm input zones, 1 alarm relay output, 2 solid output and key switch; support 1 master * code, 3 user code, 1 duress code and 1 door code
* Support wireless receiver, wireless remote controller and wireless detector
* LCD displaying operation instruction and sensor status
* Bus output
 
→Single zone expansion module CX-7401/2

* DIP or single address code module
* High stability
* Directly connected bus, static current 50 UA
* Fit for perimeter alarm sysem

8 zones expansion module CX-7408

* 1.6m away from CX-7448 Bus
* Power from control panel or dependently
* Static power consumption 10MA
* Work power DC12V

CX-32B 32 Relay

CX-32B is a 32 relay output appliance, when CX-7448 could not meets requirement, use CX-32B. There are two ways of connection with CX-7448 alarm system: connected with CX-7448 main board, or connected with computer
LED indicator
When the system works normally, LED lights. When outputting signal trigger a relay, the relative LED will light
 
BUS system Intelligent Wired Alarm System CX-7448>Output setting 

Alarm output from each zone can be controlled by jumper, the method is as follow:
One to one: No.1 zone alarm, it trigger relay 1
One to more: No.1 zone alarms, relay1, 3, 5 will be activated
More to one: No.1, 3or 8 alarm, one relay will be activated.

BUS system Intelligent Wired Alarm System CX-7448>Auto or manually restoring relay

Auto restoring relay through DIP, manual restoring is required.